Testing Results

Blevins Elementary

Posted

SCI collected “first draw” samples which consisted of collecting a water sample from each fixture or sample location after it remained stagnant for at least eight hours. Prior to sampling, SCI first mobilized to the site to flush the identified potable water fixtures throughout the structure. Once each fixture was flushed, a sign was placed on the fixture indicating it should not be used. SCI then revisited the site, after a minimum of eight hours, to collect water samples from the fixtures.

On July 18, 2023, SCI initially collected 39 drinking water samples (BVES-1 through BVES-40) from various water fixtures located throughout the structure and submitted them for analytical testing. A sample number was inadvertently skipped in the field resulting in sample identification up to BVES-40. During this sampling event, 6 sample locations exceeded the action level (AL) of 5.0 micrograms lead per liter of water. One fixture was removed, the other five were taken out of service until remediation activities could be completed.

During SCI’s resampling event on January 12, 2024, 10 drinking water samples were collected from fixtures which exceeded 5.0 micrograms lead per liter of water. In addition to first draw samples, SCI also collected second draw samples during the resampling event. The second draw sample was collected after the first draw sample and consisted of flushing the fixture for approximately 30 seconds and then collecting the sample. The purpose of the second draw sample is to aid in pinpointing any potential lead contamination and determine appropriate remediation. During this resampling event, 5 sample locations exceeded the AL, and further remediation activities were recommended.

During SCI’s resampling event on June 19, 2024, 5 drinking water samples were collected from fixtures which exceeded the AL. During this sampling event, 2 fixtures were under the AL and were returned back to service. The remaining 3 fixtures were above the AL, and further remediation activities were recommended.

During the resampling event on November 27, 2024, the three sample locations that had previously exceeded the AL were retested. During this sampling event, the locations were still above the AL, and further remediation activities were recommended.

On July7, 2025, SCI remobilized to the site to sample the three fixtures which had previously exceeded the AL. During this sampling event, all locations were below the AL and were returned to service. All drinking water samples were analyzed for total lead by U.S. EPA Method 200.8. SCI collected a minimum of 250 milliliters of water from each location. Sampled water was containerized in laboratory-provided sample containers and shipped to the accredited lab using standard chain-of-custody procedures.

The drinking water samples were analyzed for lead in accordance with the GTLOSDWA Section 160.077, which establishes an action level (AL) of 5 parts per billion (ppb). The drinking water samples which initially exceeded the AL are identified in Table 1, below. Additionally, the results of SCI’s resampling efforts are included in the right-hand columns below. Results in bold from SCI’s resampling indicate a result greater than the AL. A copy of the analytical test results and chain-of-custody for all samples is enclosed.

Sample Number Sample Location Sample Description Initial Result (ppb) Resampling - First Draw (ppb) Resampling - Second Draw (ppb) Second Resample (ppb) Third Resample (ppb) Fourth Resample (ppb)
BVES-15 Kitchen Food Line Sink 8.71 33.9 1.3 2.93 NS
BVES-16 Kitchen Food Prep Right Sink 15.1 20.0 1.3 2.67 NS
BVES-22 Kitchen Left Faucet Triple Basin Sink 13.9 79.8 6.3 14.7 35 4.26
BVES-23 Kitchen Center Faucet Triple Basin Sink 22.5 42.8 23.3 6.51 14.4 4.41
BVES-24 Kitchen Right Faucet Triple Basin Sink 32.3 47.1 12.0 14.8 21.8 3.03

NS – Not Sampled

As previously mentioned, no drinking water samples exceeded the AL of 5 ppb. Therefore, all tested fixtures are compliant per GTLOSDWA and should be tested every five years.

Download the Report (PDF)