Early Childhood - Eureka
Updated

SCI collected 14 drinking water samples from various water fixtures located throughout the structure and submitted them for analytical testing. The drinking water samples were analyzed for lead in accordance with the “Get the Lead Out of School Drinking Water Act”, Section 160.077, which establishes an action level (AL) of 5 parts per billion (ppb). The drinking water samples which exceeded the AL are identified below.

Sample Location Sample Description Result (ppb) 1st Remediation Retest 1st Draw Result Retest 2nd Draw Result 2nd Remediation Returned to Service
Staff Lounge Sink 5.65 replaced aerator <1.0 <1.0 1/17/2024 1/17/24
Hallway Outside Conference Room Water Fountain 7.09   4.06      
Hallway Outside Conference Room Bottle Filler 6.34   8.84      
Kitchen Three Basin Sink Left Sink 30.4 replaced aerator 111 18.3 replaced fixture marked as non-potable
Kitchen Three Basin Sink Right Sink 60.1 replaced aerator 62.1 571 replaced fixture marked as non-potable
Kitchen Handwash Sink 37.5 replaced aerator 50.1 5.1 replaced fixture 9/20/24
Nurse's Office Sink 6.05 replaced aerator 8.3 <1.0 replaced fixture marked as hand wash only
Nurse's Office Fridge Ice Machine 29.7 shut off        
Hallway Outside 2nd Floor Bathroom Water Fountain 7.04   1.39      